Bias Adjustment

IMG_7163

Hunt Amplification uses the most accurate biasing method: 

I measure the actual output tube plate current, and adjust for your desired tone within the safe operating range of the output stage.  

This method is far superior to the "crossover notch" biasing technique and allows for more consistent tone between different sets of tubes.  That said, I do examine the output waveform on every amp.

Questions?  Give me a call or send me an email.